Guide · EWS1 A1
What does an EWS1 A1 rating mean?
A quick, plain-English answer for leaseholders, buyers and agents, with what an A1 means for a sale or remortgage.
In short: An A1 is the cleanest result an EWS1 form can give. The external walls are unlikely to support combustion, and there are no attachments, such as balconies, with significant combustible material. No remedial works are needed, and lenders normally treat it as satisfactory.
Need an EWS1 for a sale or remortgage? We carry out PAS 9980 FRAEWs and EWS1 assessments, with our own access and opening-up team. See our FRAEW & EWS1 assessments or contact us for a quote.
What A1 means on the form
The EWS1 form has two options. Option A is for buildings whose external wall materials are unlikely to support combustion. Option B is for buildings where combustible materials are present. Option A has three outcomes: A1, A2 and A3.
A1 is the outcome where the wall materials are unlikely to support combustion and there are no attachments, such as balconies, whose construction includes significant quantities of combustible material.
Typical A1 buildings have masonry or concrete walls, mineral wool insulation, and metal or glass balconies with non-combustible decking, or no balconies at all.
Is A1 better than B1?
Both are satisfactory outcomes, and neither needs remedial works. The difference is what was found. A1 means the walls are unlikely to support combustion. B1 means combustible materials are present, but a fire safety professional has judged the risk acceptable. See what a B1 rating means.
In practice, most lenders treat A1, A2 and B1 in the same way. Each lender sets its own policy.
Who can sign an A1
An Option A form can be signed by a member of a relevant professional body within the construction industry. It does not need a fire engineer, because the signatory is confirming what the walls are made of rather than judging a fire risk. Option B needs a signatory with fire safety expertise.
The signatory still needs good evidence of the wall build-up. Drawings alone are often not enough, because walls are not always built as drawn. See walls that differ from the drawings.
How an A1 is reached
The signatory needs to know what every wall type is made of, including insulation, cavity barriers and anything fixed to the outside. On most buildings this comes from a FRAEW to PAS 9980, which records each wall type, often by opening it up, and appraises the fire risk. Our intrusive investigations provide the evidence where records are missing.
If balconies or other attachments contain combustible material, the outcome cannot be A1. It will be A2 or A3, depending on whether a risk assessment shows that remedial works are needed.
How long an A1 lasts
An EWS1 is valid for up to five years. It can be replaced sooner if the walls change, or if new information comes to light about the materials.
Do you still need an EWS1 at all?
From 1 November 2026, RICS guidance says valuers should request an EWS1 only where there is a clear reason to. In some cases a FRAEW summary can be relied on instead. See what an EWS1 form is.
Frequently asked questions
What does EWS1 A1 mean?
The external wall materials are unlikely to support combustion, and there are no attachments with significant combustible material. No remedial works are needed.
Is an A1 EWS1 rating good?
Yes. It is the most straightforward outcome and is normally accepted by lenders for valuation.
What is the difference between A1 and A2?
Both mean the walls are unlikely to support combustion. A2 means attachments such as balconies do contain combustible material, but a risk assessment shows no remedial works are needed.
Can an A1 be signed without a fire engineer?
Yes. Option A forms can be signed by a member of a relevant professional body within the construction industry.
How long is an A1 EWS1 valid?
Up to five years, unless the walls change or new information emerges.