What does an EWS1 A2 rating mean?

A quick, plain-English answer for leaseholders, buyers and agents, with what an A2 means for a sale or remortgage.

MTC GuideLeaseholders, buyers & agentsUpdated November 2026

In short: An A2 means the external walls are unlikely to support combustion, but attachments such as balconies do contain combustible material. A risk assessment has shown that no remedial works to those attachments are needed. Lenders normally treat it as a satisfactory result.

Timber or composite balconies on your building? We assess attachments as part of a PAS 9980 FRAEW and can sign the EWS1. See our FRAEW & EWS1 assessments or contact us for a quote.

What A2 means on the form

Option A of the EWS1 form covers buildings whose external wall materials are unlikely to support combustion. It has three outcomes. A1 means there are no attachments with significant combustible material. A2 means there are, but an adequate risk assessment shows no remedial works are needed. A3 means remedial works to the attachments may be needed.

The A2 outcome therefore depends on two things: what the attachments are made of, and a risk assessment of them.

What counts as an attachment

Attachments are things fixed to the outside of the wall rather than part of it. The most common are balconies, but they also include solar shading, brise soleil, privacy screens and planters.

Combustible material in an attachment is often timber or composite decking, timber soffits, or plastic balcony screens. See balconies and attachments for how these are found and assessed.

Is A2 a bad rating?

No. An A2 confirms that no remedial works are needed. Most lenders treat A1, A2 and B1 alike, although each sets its own policy.

An A2 can change if the attachments change. Replacing decking or screens with different products may need a new assessment.

How the risk assessment works

The assessor looks at how much combustible material there is, where it sits, whether fire could spread from one balcony to the next, the height of the building, how it is used and how people escape. Stacked balconies with timber decking on a tall residential building carry more risk than a single timber screen at low level.

On most buildings this is done as part of a FRAEW to PAS 9980, which appraises the walls and attachments together.

Who can sign an A2

Like all Option A forms, an A2 can be signed by a member of a relevant professional body within the construction industry. Where the attachment risk is not clear-cut, the signatory may need advice from someone with fire safety expertise.

How long an A2 lasts

An EWS1 is valid for up to five years, unless the building changes or new information emerges.

Do you still need an EWS1 at all?

From 1 November 2026, RICS guidance says valuers should request an EWS1 only where there is a clear reason to. In some cases a FRAEW summary can be relied on instead. See what an EWS1 form is.

Frequently asked questions

What does EWS1 A2 mean?

The walls are unlikely to support combustion. Attachments such as balconies contain combustible material, but a risk assessment shows no remedial works are needed.

Is an A2 EWS1 acceptable to lenders?

Usually, yes. Most lenders treat A2 in the same way as A1 and B1, but each lender sets its own policy.

What is the difference between A2 and A3?

In both, attachments contain combustible material. In A2 the risk assessment shows no works are needed. In A3 remedial works to the attachments may be needed.

Do timber balconies always mean an A2 or A3?

Not always. It depends on how much timber there is and where. Timber balconies with significant combustible material rule out A1.

How long is an A2 EWS1 valid?

Up to five years, unless the attachments or walls change.

Sources and guidance

Related reading

Talk to us

Need an EWS1 for your building?

We carry out PAS 9980 FRAEWs and EWS1 assessments across the UK, backed by on-site evidence.

© McKay Turner Consulting LtdGuide: EWS1 A2 rating